Sign In Join Help
 
Filtemc Electronic Equipment Co.,Ltd

 
 
Recommended Results 
 
AC 3 phases 4 lines series filters 

  Category : Energy and raw material->Others->EMI

     
AC 3 phases 4 lines series filters
 
 
       

  Product Specification
 
  Model No:      AC 3 phases 4 lines series filters
CountryCN
Brandfiltemc
Materials
size
Weight1.6
ColorWhite
PackingCarton box
Minimum Order500
Payment TermT/T

 

    Product Detail
  AC 3 phases 4 lines series filters
1.Features&Applications:
Low leakage current,good performance of common mode and differential mode interference suppression.
Widely used in machine tool device,inverter power supply,inverter equipment,industry equipment and medical appliance,etc.
Rated current:1A-400A.
2. Technical data:
Rated voltage:250/440VAC
Test voltage:2250VDC(line to line) and 2700VDC(line to ground).
Climatic category:25/085/21.
Operating frenquency:50/60Hz.
Insulation resistance:>200MΩat500VDC.
3.Tabulates
FT310-6:6A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.38Kg(Weight).
FT310-10:10A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.51Kg(Weight).
FT310-20:20A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.60Kg(Weight).
FT310-50:50A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.1(Electrical schematics),M6Stud(Termination),1.0Kg(Weight).
FT310-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M8Stud(Termination),3.2Kg(Weight).
FT310-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M10Stud(Termination),3.0Kg(Weight).
FT320-10:10A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).

FT320-20:20A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT320-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.4(Dimension),
Fig.2(Electrical schematics),M6Stud(Termination),1.6Kg(Weight).
FT320-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.2(Electrical schematics),M8Stud(Termination),6.0Kg(Weight).
FT320-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.2(Electrical schematics),M10Stud(Termination),7.0Kg(Weight).
FT320-200:200A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.2(Electrical schematics),M10Stud(Termination),11.5Kg(Weight).
FT3200-6:6A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.65Kg(Weight).
FT3200-10:10A(Ratedcurrent),
<3.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.65Kg(Weight).
FT3200-20:20A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT3200-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.3(Electrical schematics),M6Stud(Termination),3.2Kg(Weight).
If you want to get information about Dimension and outline drawing,Electrical schematics,Insertion loss(dB),please contact with(Xu Kuishan)Filtemc Electronic Equipment Co.,Ltd


AC 3 phases 4 lines series filters
1.Features&Applications:
Low leakage current,good performance of common mode and differential mode interference suppression.
Widely used in machine tool device,inverter power supply,inverter equipment,industry equipment and medical appliance,etc.
Rated current:1A-400A.
2. Technical data:
Rated voltage:250/440VAC
Test voltage:2250VDC(line to line),1760VDC(line to neutral) and 2700VDC(line to ground).
Climatic category:25/085/21.
Operating frenquency:50/60Hz.
Insulation resistance:>200MΩat500VDC.
3.Tabulates
FT410-6:6A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.4Kg(Weight).
FT410-10:10A(Ratedcurrent),
<2.0MA(Leakagecurrent250VAC/50Hz),Fig.1(Dimension),
Fig.1(Electrical schematics),M4Stud(Termination),0.4Kg(Weight).
FT410-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M8Stud(Termination),3.1Kg(Weight).
FT410-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.1(Electrical schematics),M10Stud(Termination),3.1Kg(Weight).
FT420-10:10A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT420-20:20A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.3(Dimension),
Fig.2(Electrical schematics),M6Stud(Termination),1.0Kg(Weight).
FT420-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.2(Electrical schematics),M6Stud(Termination),3.0Kg(Weight).
FT420-100:100A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.2(Electrical schematics),M8Stud(Termination),4.0Kg(Weight).
FT4200-6:6A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.6Kg(Weight).
FT4200-10:10A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.2(Dimension),
Fig.3(Electrical schematics),M4Stud(Termination),0.6Kg(Weight).
FT4200-50:50A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.3(Electrical schematics),M6Stud(Termination),3.0Kg(Weight).
FT4200-150:150A(Ratedcurrent),
<5.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.3(Electrical schematics),M10Stud(Termination),5.6Kg(Weight).
FT430-10:10A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.4(Dimension),
Fig.4(Electrical schematics),M4Stud(Termination),1.0Kg(Weight).
FT430-20:20A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.4(Dimension),
Fig.4(Electrical schematics),M6Stud(Termination),1.5Kg(Weight).

FT430-50:50A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.5(Dimension),
Fig.4(Electrical schematics),M6Stud(Termination),3.1Kg(Weight).
FT430-100:100A(Ratedcurrent),
<8.0MA(Leakagecurrent250VAC/50Hz),Fig.6(Dimension),
Fig.4(Electrical schematics),M8Stud(Termination),6.9Kg(Weight).
If you want to get information about Dimension and outline drawing,Electrical schematics,Insertion loss(dB),please contact with(Xu Kuishan)Filtemc Electronic Equipment Co.,Ltd


   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .